Electrical products

The products include components for the start, stop, regulation and monitoring of fans and filter units.

The group includes:

  • Filter control of cleaning sequences.
  • Y-D starters for the motor overload protection.
  • Frequency converters for rPM control.

Equipment for the monitoring of:

  • Suction capability on units (whether the extraction is sufficient).
  • Temperatures in units (regarding prevention of fire).
  • Waste volume (in e.g. dust container).

Do you not know what you need? Please, contact our sales team that is ready to help you.

+45 74 52 30 75

System monitoring
System guard for statutory monitoring of process extraction
  • L_Systemguard
    System guard L

    System guard type L meets the governmental demands for system monitoring in extraction units. Is delivered as complete package. Simple, stabile and easy to Mount.

    • System guard L0 is used for measuring range: 20-300 Pa
    • System guard L1 is used for measuring range: 200-1,000 Pa
    • System guard L3 is used for measuring range: 1,000-4,000 Pa
    • System guard L4 is used for measuring range: 2,300-21,500Pa
    • The product is CE-marked
    • Maximum differential pressure: 40mbar (4000 Pa), L0, L1, L3
    • Maximum differential pressure: 600mmbar (60kPa), L4
    • All versions are available with electric bulb or LED
Start/stop control
Smart Power equipment for automatic start/stop of dampers and fans
  • SPKU_SmartPowerPowerSocket
    Smart Power Socket SPKU

    Smart Power socket can control start/stop of fans and motor damper in connection with process extraction.

    • Dependable component for start/stop-control
    • Equipped with touch-folie and diode on front
    • After-run time: adjustable between 1 sec and 4 minutes
    • Socket available in 16, 32 and 64 ampere
    • 16 ampere power socket is available with 230V-plug
  • SPB_SmartPowerBox
    Smart Power Box SPB

    Smart Power Box is used as start/stop-control of several dampers/machines by e.g. micro-switch/potential free switches.

    • Dependable component for start/stop-control
    • Integrated 230VAC/24VDC-transformer
    • Equipped with touch-folie and diode on front
    • After-run time: adjustable between 1 sec and 4 minutes
    • Max. load 400 Watt. Protected with 2 Amp relay
Motor protection
Motor protection switches and starters for thermal motor protection
  • HBM_HBM-Protection_ABB-DMS132G
    Motor protection HBM

    Motor protection switch is used to start and stop a motor, e.g. in connection with a fan. Protects against short circuit, overload and phase failure.

    • Durable reliable motor protection switch
    • Easy, technical way to start and stop a motor
    • Suitable for workshop environment
    • Designed and tested according to EN 60947
  • MBM_IMG_MBM
    Motor protection MBM

    Motor protection switch is used to start and stop a motor, e.g. in connection with a fan. Protects against short circuit, overload and phase failure.

    • Durable reliable motor protection switch
    • Easy, technical way to start and stop a motor
    • Suitable for workshop environment
    • Designed and tested according to EN 60947
  • MSYD_MSYD-Motorstarter
    Motor starter MSYD

    Motor starter Y-D is used to start a larger motor. Can be controlled remotely by a contact box. Is used among other things on filter unit type FL for process extraction.

    • Automatic start-delta starter
    • Protects the wiring
    • Easy operation
    • Control voltage 230 VAC
    • IP 65 protected
    • Approved according tol EN 60947
    • Y-D-motor starters can be used for Gram fans type VE and RV from 5.5kW
Motor control
Frequency converters and pressure control for fans
  • VLT_IMG_VLT-FC102
    Frequency converter VLT FC102

    Compact and user-friendly frequency converter type VLT FC102 for use as fan starter and regulator. Operated by digital display on converter front.

    • Compact, user-friendly design
    • Including instructions for PID-regulation
    • User-friendly display on converter front
    • Available in 17 versions for kW between 1.10 - 90.00
    • Applicable for max. ampere between 2.70 and 161.00.
    • Supply 3 x 400 VAC, 3 phase + N + PE
  • TRDU_PressureTransducer0-5KPA
    Differential pressure transmitter TRDU

    Gram pressure transmitter is excellent as signaller for frequency converters (with PID-regulation). Available in two types for pressure ranges from 0 to 50 kPa.

    • Quick and easy mounting
    • Supply: 10-35 VDC (2-cable supply)
    • Favorable price
    • Advantageous performance ratio
Filter controls
Filter controls with timer or differential pressure as well as leck detector
  • TC1_IMG_TC1
    Filter control TC1

    Filter control is used for the cleaning of pleated filter cartridges for easy and cost effective automatic solution.

    • Filter control with timer-kontrol
    • Easy setting of cleaning impulse and interval time
    • Mounted directly on jet valve
    • Mainly for weather-protected application
  • ECOS_ECO-06S-Control
    Differential pressure control ECO-S 4, 6, 12 and 20

    Controls cleaning of compressed-air cleaned filter units. Cleans at a very high differential pressure above the filter cartridges. When the fan stops, the automatic after-cleaning begins

    • Control ECO-S provides sustantial energy consumption optimization
    • Only filter cartridge cleaning as needed
    • Protects the filter cartridges
    • Easy programming
    • Shows differential pressure on display
Monitoring
Equipment for monitoring of filling and temperature
  • RT_RT101
    Temperature sensor RT101

    Temperature sensor RT101 for signaling at high temperatures in units/channels, e.g. in the case of a fire. Has standard potential-free open/close switch

    • RT101 ensures alarm at fire
    • Must be connected to signal device or acoustic sounder
    • Simple mounting
    • Adjustable between 25°C and 90°C
  • RP_Laek-detektor_til_hjemmeside
    Leak Detector Type RP 04/ SDM-1

    Leak detector type RP 04/ SDM-1 can be used in connection with filter systems, where monitoring the amount of particles in the exhaust air and alarming at elevated concentrations are required.

    • Leak detector type RP 04 / SDM-01 for detecting dust emissions down to 0.1mg/m3
    • Supply voltage: 24VAC / 115VAC / 230VAC +/-15%, 50-60Hz
    • Temperature range: -10°C to +60°C
    • Relay outputs: 10A 250VAC / 10A 30VDC
    • Max power consumption: 10VA-10W
    • IP Rating: IP56
  • OEM-K_OEM-K_Complete
    Fill-level sensor OEM-K

    Fill-level sensor OEM-K is used, when you require to get an alarm at filled dust container and the like, e.g. in connection with cyclones and filter units.

    • Short reaction time
    • Easy setting of sensibility
    • Supply voltage 230VAC
    • Ensures for overfilled dust container
    • Signal device or sounder can be connected
Signal devices
Signal devices with light and/or sounder
  • ALA_VariousLamps
    Signal devices ALA

    For all forms of monitoring, including Gram system guard, a wide range of signal devices for both visual and acoustic alarm is available.

    • Simple, specially selected signal devices
    • Meet demands regarding system monitoring
    • Tested and dependable
    • Components easy to mount
    • Visual alarm
    • Acoustic alarm